Fault finder: Medicine reminder pill box
10 checks for this build on the Nano. Work from the top: power first, then each part, then the code.
0 of 10 checked
Power🔧 DC volts, 20 V rangeCheck 1 of 10
Nano supply pin
Plug the Nano into USB. Black probe on a GND pin, red probe on the 5V pin of the board.
You should see: 4.6 to 5.3 V
Readings are compared with the ranges for this build's parts. A meter on the wrong range or a loose probe gives odd numbers: check those first.
Common faults in this build
The alarm never stops even when the lid is open: what should I check?
The reed logic may be reversed. If the switch is closed with the lid open, flip the magnet or swap HIGH and LOW in lidOpen.
The clock is wrong: what should I check?
Set it again with rtc.adjust and replace the CR2032 battery on the DS3231.
The LCD is blank: what should I check?
Adjust the contrast and try 0x3F.
Wrong compartment lights: what should I check?
dayOfTheWeek counts from Sunday = 0. Wire LED 1 to Sunday.