Fault finder: Magnet drop timer
11 checks for this build on the Nano. Work from the top: power first, then each part, then the code.
0 of 11 checked
Power🔧 DC volts, 20 V rangeCheck 1 of 11
Nano supply pin
Plug the Nano into USB. Black probe on a GND pin, red probe on the 5V pin of the board.
You should see: 4.6 to 5.3 V
Readings are compared with the ranges for this build's parts. A meter on the wrong range or a loose probe gives odd numbers: check those first.
Common faults in this build
No trigger: what should I check?
Turn the magnet round, move the sensor closer or use a stronger magnet.
Time is tiny in copper: what should I check?
Check you used a copper pipe and that the sensors are far enough apart.
Triggers by itself: what should I check?
Move the sensors away from other magnets and metal.
Display blank: what should I check?
Check the OLED address 0x3C.
Magnet sticks: what should I check?
Use a thinner magnet or a larger pipe.