Fault finder: Machine run-hours meter

11 checks for this build on the Nano. Work from the top: power first, then each part, then the code.

0 of 11 checked
Power🔧 DC volts, 20 V rangeCheck 1 of 11

Nano supply pin

Plug the Nano into USB. Black probe on a GND pin, red probe on the 5V pin of the board.

You should see: 4.6 to 5.3 V

V

Readings are compared with the ranges for this build's parts. A meter on the wrong range or a loose probe gives odd numbers: check those first.

Common faults in this build

Always RUNNING: what should I check?

Turn the module's pot to lower the sensitivity.

Never RUNNING: what should I check?

Turn the pot up, or fix the sensor firmly against the machine body.

Hours lost after power cut: what should I check?

The total saves every 10 running minutes and when it stops.

Display blank: what should I check?

Check the OLED address 0x3C and the wires.

Counts too fast: what should I check?

Make sure the sensor is not picking up the table or other machines.