Fault finder: Digital hanging scale
11 checks for this build on the Nano. Work from the top: power first, then each part, then the code.
0 of 11 checked
Power🔧 DC volts, 20 V rangeCheck 1 of 11
Nano supply pin
Plug the Nano into USB. Black probe on a GND pin, red probe on the 5V pin of the board.
You should see: 4.6 to 5.3 V
Readings are compared with the ranges for this build's parts. A meter on the wrong range or a loose probe gives odd numbers: check those first.
Common faults in this build
Reading goes negative when loaded: what should I check?
Swap A+ and A- or use a negative CAL_FACTOR.
Reading is unstable: what should I check?
Keep wires short, use a clean 5 V supply and let the cells warm up for a minute.
One sensor reads wrong: what should I check?
Check each half-bridge has red, black and white wire in the right place.
Reading changes with hook position: what should I check?
The load is not centred. Add a mechanism so the weight hangs under the middle.