Fault finder: Digital hanging scale

11 checks for this build on the Nano. Work from the top: power first, then each part, then the code.

0 of 11 checked
Power🔧 DC volts, 20 V rangeCheck 1 of 11

Nano supply pin

Plug the Nano into USB. Black probe on a GND pin, red probe on the 5V pin of the board.

You should see: 4.6 to 5.3 V

V

Readings are compared with the ranges for this build's parts. A meter on the wrong range or a loose probe gives odd numbers: check those first.

Common faults in this build

Reading goes negative when loaded: what should I check?

Swap A+ and A- or use a negative CAL_FACTOR.

Reading is unstable: what should I check?

Keep wires short, use a clean 5 V supply and let the cells warm up for a minute.

One sensor reads wrong: what should I check?

Check each half-bridge has red, black and white wire in the right place.

Reading changes with hook position: what should I check?

The load is not centred. Add a mechanism so the weight hangs under the middle.