Fault finder: Four-level battery indicator

9 checks for this build on the board. Work from the top: power first, then each part, then the code.

0 of 9 checked
Power🔧 DC volts, 20 V rangeCheck 1 of 9

board supply pin

Plug the board into USB. Black probe on a GND pin, red probe on the 5V pin of the board.

You should see: 4.6 to 5.3 V

V

Readings are compared with the ranges for this build's parts. A meter on the wrong range or a loose probe gives odd numbers: check those first.

Common faults in this build

No LED lights: what should I check?

Check the LED direction and the output pins.

All LEDs always on: what should I check?

Check the sense node and that pins 4, 6, 8, 10 are joined.

LEDs light in the wrong order: what should I check?

Check the ladder order of the taps.

Zener node is low: what should I check?

Check the 1 kilohm and the Zener direction.

LEDs very dim: what should I check?

Use 1 kilohm resistors, not larger ones.