Fault finder: LiPo cell checker with alarm
10 checks for this build on the Nano. Work from the top: power first, then each part, then the code.
0 of 10 checked
Power🔧 DC volts, 20 V rangeCheck 1 of 10
Nano supply pin
Plug the Nano into USB. Black probe on a GND pin, red probe on the 5V pin of the board.
You should see: 4.6 to 5.3 V
Readings are compared with the ranges for this build's parts. A meter on the wrong range or a loose probe gives odd numbers: check those first.
Common faults in this build
Readings too high: what should I check?
Check the divider resistor values.
Cell 1 reads wrong: what should I check?
Check the lead pin order.
Display blank: what should I check?
Check the I2C address and wiring.