Fault finder: Pocket lux meter
9 checks for this build on the Nano. Work from the top: power first, then each part, then the code.
0 of 9 checked
Power🔧 DC volts, 20 V rangeCheck 1 of 9
Nano supply pin
Plug the Nano into USB. Black probe on a GND pin, red probe on the 5V pin of the board.
You should see: 4.6 to 5.3 V
Readings are compared with the ranges for this build's parts. A meter on the wrong range or a loose probe gives odd numbers: check those first.
Common faults in this build
BH1750 not found: what should I check?
Check SDA and SCL, and that ADDR is not tied to 3.3 V (that gives address 0x5C).
Display blank: what should I check?
Try address 0x3D, or check the display voltage.
Value stuck at 0: what should I check?
Wait for the first conversion and check the power-on command.
Readings seem low: what should I check?
Shadows from your hand or the breadboard, hold it clear.
Both devices fail: what should I check?
Duplicate addresses or loose wires on the shared bus.