Fault finder: LED and Zener tester
9 checks for this build on the Nano. Work from the top: power first, then each part, then the code.
0 of 9 checked
Power🔧 DC volts, 20 V rangeCheck 1 of 9
Nano supply pin
Plug the Nano into USB. Black probe on a GND pin, red probe on the 5V pin of the board.
You should see: 4.6 to 5.3 V
Readings are compared with the ranges for this build's parts. A meter on the wrong range or a loose probe gives odd numbers: check those first.
Common faults in this build
Always shows No part: what should I check?
The LED is backwards or the test node is not connected to A0.
LM317 gets warm: what should I check?
It drops most of 12 V at 12.5 mA, so it dissipates little, but check the resistor value.
Readings jump: what should I check?
Use short leads and the 32-sample average. A noisy 12 V adapter can also shift readings, so add 100 nF across Nano 5V and GND.
Zener above 8 V reads No part: what should I check?
The source runs out of headroom. Use a higher supply for those parts.