Projects / Door knock counter / Fault finder

Fault finder: Door knock counter

7 checks for this build on the Uno. Work from the top: power first, then each part, then the code.

0 of 7 checked
Power🔧 DC volts, 20 V rangeCheck 1 of 7

Uno supply pin

Plug the Uno into USB. Black probe on a GND pin, red probe on the 5V pin of the board.

You should see: 4.6 to 5.3 V

V

Readings are compared with the ranges for this build's parts. A meter on the wrong range or a loose probe gives odd numbers: check those first.

Common faults in this build

Every knock counts twice: what should I check?

Increase LOCKOUT_MS to 200.

Nothing counts: what should I check?

Lower THRESHOLD and check the 1 megohm resistor is in place.

Random counts: what should I check?

A loose disc or lead is buzzing, tape it down firmly.

Readings stay high: what should I check?

Check the diode orientation and the 1 megohm resistor.

LED stays on: what should I check?

Check the LED legs and the pin number.