Fault finder: Kitchen chimney that starts on smoke and heat

9 checks for this build on the Nano. Work from the top: power first, then each part, then the code.

0 of 9 checked
Power🔧 DC volts, 20 V rangeCheck 1 of 9

Nano supply pin

Plug the Nano into USB. Black probe on a GND pin, red probe on the 5V pin of the board.

You should see: 4.6 to 5.3 V

V

Readings are compared with the ranges for this build's parts. A meter on the wrong range or a loose probe gives odd numbers: check those first.

Common faults in this build

Fan starts by itself: what should I check?

Raise SMOKE_RISE or wait for the MQ-2 to settle.

Never starts on smoke: what should I check?

Lower SMOKE_RISE or move the sensor nearer the hob.

Display blank: what should I check?

Try address 0x3F.