Fault finder: Home data with InfluxDB and Grafana
11 checks for this build on the ESP32. Work from the top: power first, then each part, then the code.
0 of 11 checked
Power🔧 DC volts, 20 V rangeCheck 1 of 11
ESP32 supply pin
Plug the ESP32 into USB. Black probe on a GND pin, red probe on the 3V3 pin of the board.
You should see: 3.15 to 3.45 V
Readings are compared with the ranges for this build's parts. A meter on the wrong range or a loose probe gives odd numbers: check those first.
Common faults in this build
HTTP code 401: what should I check?
Check the token and the organisation name.
HTTP code 404: what should I check?
Check the bucket name in the URL.
No panel data: what should I check?
Check the time range and the Flux query.