Fault finder: NFT hydroponics pump and water level guard
8 checks for this build on the Nano. Work from the top: power first, then each part, then the code.
0 of 8 checked
Power🔧 DC volts, 20 V rangeCheck 1 of 8
Nano supply pin
Plug the Nano into USB. Black probe on a GND pin, red probe on the 5V pin of the board.
You should see: 4.6 to 5.3 V
Readings are compared with the ranges for this build's parts. A meter on the wrong range or a loose probe gives odd numbers: check those first.
Common faults in this build
Pump runs when the reservoir is low: what should I check?
The float logic is the wrong way. Flip it.
Timer shows odd values: what should I check?
Use unsigned long for all times.
No display: what should I check?
Check the LCD address and wiring.
Relay never clicks: what should I check?
Active-low versus active-high mismatch. Swap the HIGH and LOW writes.