Fault finder: Hinge angle gauge
13 checks for this build on the Nano. Work from the top: power first, then each part, then the code.
0 of 13 checked
Power🔧 DC volts, 20 V rangeCheck 1 of 13
Nano supply pin
Plug the Nano into USB. Black probe on a GND pin, red probe on the 5V pin of the board.
You should see: 4.6 to 5.3 V
Readings are compared with the ranges for this build's parts. A meter on the wrong range or a loose probe gives odd numbers: check those first.
Common faults in this build
Angle goes the wrong way: what should I check?
Swap the outer pot legs or recalibrate.
Reading jumps: what should I check?
The wiper is dirty or the coupling slips.
Wrong at the ends: what should I check?
The pot has reached its stops, use a smaller range.
Blank screen: what should I check?
Check A4 and A5.
Want to recalibrate: what should I check?
Clear the EEPROM or change the MAGIC value in the sketch.