Projects / Hinge angle gauge / Fault finder

Fault finder: Hinge angle gauge

13 checks for this build on the Nano. Work from the top: power first, then each part, then the code.

0 of 13 checked
Power🔧 DC volts, 20 V rangeCheck 1 of 13

Nano supply pin

Plug the Nano into USB. Black probe on a GND pin, red probe on the 5V pin of the board.

You should see: 4.6 to 5.3 V

V

Readings are compared with the ranges for this build's parts. A meter on the wrong range or a loose probe gives odd numbers: check those first.

Common faults in this build

Angle goes the wrong way: what should I check?

Swap the outer pot legs or recalibrate.

Reading jumps: what should I check?

The wiper is dirty or the coupling slips.

Wrong at the ends: what should I check?

The pot has reached its stops, use a smaller range.

Blank screen: what should I check?

Check A4 and A5.

Want to recalibrate: what should I check?

Clear the EEPROM or change the MAGIC value in the sketch.