Projects / Hand-wash timer / Fault finder

Fault finder: Hand-wash timer

9 checks for this build on the Nano. Work from the top: power first, then each part, then the code.

0 of 9 checked
Power🔧 DC volts, 20 V rangeCheck 1 of 9

Nano supply pin

Plug the Nano into USB. Black probe on a GND pin, red probe on the 5V pin of the board.

You should see: 4.6 to 5.3 V

V

Readings are compared with the ranges for this build's parts. A meter on the wrong range or a loose probe gives odd numbers: check those first.

Common faults in this build

Stays at 20: what should I check?

Check the hand is within 25 cm and the sensor wires are on A4 and A5.

Display blank: what should I check?

Check the OLED address 0x3C and the power wires.

Stops at lox begin: what should I check?

Check the sensor power and I2C wires.

Counts when nothing is there: what should I check?

Shield the sensor from reflections off the basin.

No beep: what should I check?

Check the buzzer is passive and on D8.