Fault finder: 20-second hand wash timer
6 checks for this build on the Nano. Work from the top: power first, then each part, then the code.
0 of 6 checked
Power🔧 DC volts, 20 V rangeCheck 1 of 6
Nano supply pin
Plug the Nano into USB. Black probe on a GND pin, red probe on the 5V pin of the board.
You should see: 4.6 to 5.3 V
Readings are compared with the ranges for this build's parts. A meter on the wrong range or a loose probe gives odd numbers: check those first.
Common faults in this build
The ring starts without a hand: what should I check?
Turn the IR trimmer so the sensor LED is off when nothing is near, and keep sunlight off it.
The ring flickers: what should I check?
Add the 100 µF capacitor and use a solid ground wire.
Only some LEDs light: what should I check?
Check ring orientation: DIN is the input pad.
No tune: what should I check?
Use a passive buzzer, not an active one, and check D8.