Fault finder: 20-second hand wash timer

6 checks for this build on the Nano. Work from the top: power first, then each part, then the code.

0 of 6 checked
Power🔧 DC volts, 20 V rangeCheck 1 of 6

Nano supply pin

Plug the Nano into USB. Black probe on a GND pin, red probe on the 5V pin of the board.

You should see: 4.6 to 5.3 V

V

Readings are compared with the ranges for this build's parts. A meter on the wrong range or a loose probe gives odd numbers: check those first.

Common faults in this build

The ring starts without a hand: what should I check?

Turn the IR trimmer so the sensor LED is off when nothing is near, and keep sunlight off it.

The ring flickers: what should I check?

Add the 100 µF capacitor and use a solid ground wire.

Only some LEDs light: what should I check?

Check ring orientation: DIN is the input pad.

No tune: what should I check?

Use a passive buzzer, not an active one, and check D8.