Fault finder: Greenhouse trend monitor

13 checks for this build on the ESP32. Work from the top: power first, then each part, then the code.

0 of 13 checked
Power🔧 DC volts, 20 V rangeCheck 1 of 13

ESP32 supply pin

Plug the ESP32 into USB. Black probe on a GND pin, red probe on the 3V3 pin of the board.

You should see: 3.15 to 3.45 V

V

Readings are compared with the ranges for this build's parts. A meter on the wrong range or a loose probe gives odd numbers: check those first.

Common faults in this build

Page will not load: what should I check?

Phone on a different network, or guest Wi-Fi blocks devices.

Soil reads 0 or 100 always: what should I check?

Recalibrate dry and wet values.

History lost: what should I check?

It lives in RAM: a reset clears it. Add the SD card logger for long runs.