Fault finder: Grain storage temperature and moisture probe

8 checks for this build on the Nano. Work from the top: power first, then each part, then the code.

0 of 8 checked
Power🔧 DC volts, 20 V rangeCheck 1 of 8

Nano supply pin

Plug the Nano into USB. Black probe on a GND pin, red probe on the 5V pin of the board.

You should see: 4.6 to 5.3 V

V

Readings are compared with the ranges for this build's parts. A meter on the wrong range or a loose probe gives odd numbers: check those first.

Common faults in this build

A probe reads -127: what should I check?

Check its wiring and the shared pull-up.

Only two probes found: what should I check?

Check each data wire joins the bus.

No display: what should I check?

Try LCD address 0x3F.

False warnings: what should I check?

Probes in different sun or draught; keep them in the same bin.