Fault finder: LPG gas leak alarm
8 checks for this build on the Uno. Work from the top: power first, then each part, then the code.
0 of 8 checked
Power🔧 DC volts, 20 V rangeCheck 1 of 8
Uno supply pin
Plug the Uno into USB. Black probe on a GND pin, red probe on the 5V pin of the board.
You should see: 4.6 to 5.3 V
Readings are compared with the ranges for this build's parts. A meter on the wrong range or a loose probe gives odd numbers: check those first.
Common faults in this build
The alarm goes off at start-up: what should I check?
It was not warmed up or started in dirty air. Restart in fresh air.
Very slow response: what should I check?
Check the module's heater is warm. A cold sensor means no 5 V.
Reading stuck at 1023: what should I check?
AO and DO swapped, or the module's sensitivity trimmer is at one end.
This is a learning project: what should I check?
For a real kitchen, also fit a certified LPG detector. Never test with an open flame.