Fault finder: Evaporation pan water loss logger
9 checks for this build on the Nano. Work from the top: power first, then each part, then the code.
0 of 9 checked
Power🔧 DC volts, 20 V rangeCheck 1 of 9
Nano supply pin
Plug the Nano into USB. Black probe on a GND pin, red probe on the 5V pin of the board.
You should see: 4.6 to 5.3 V
Readings are compared with the ranges for this build's parts. A meter on the wrong range or a loose probe gives odd numbers: check those first.
Common faults in this build
Reading wanders: what should I check?
Wind, a loose cable or a warm HX711; shield and tighten.
Reading falls as weight rises: what should I check?
Swap the A+ and A- wires.
Always zero: what should I check?
DT and SCK swapped or wrong pins.
No rows on the SD: what should I check?
Check the card is FAT32 and CS is D10.
Large negative drift: what should I check?
Temperature drift of the cell; compare night readings.