Fault finder: Evaporation pan water loss logger

9 checks for this build on the Nano. Work from the top: power first, then each part, then the code.

0 of 9 checked
Power🔧 DC volts, 20 V rangeCheck 1 of 9

Nano supply pin

Plug the Nano into USB. Black probe on a GND pin, red probe on the 5V pin of the board.

You should see: 4.6 to 5.3 V

V

Readings are compared with the ranges for this build's parts. A meter on the wrong range or a loose probe gives odd numbers: check those first.

Common faults in this build

Reading wanders: what should I check?

Wind, a loose cable or a warm HX711; shield and tighten.

Reading falls as weight rises: what should I check?

Swap the A+ and A- wires.

Always zero: what should I check?

DT and SCK swapped or wrong pins.

No rows on the SD: what should I check?

Check the card is FAT32 and CS is D10.

Large negative drift: what should I check?

Temperature drift of the cell; compare night readings.