Fault finder: ECG heart signal plotter
5 checks for this build on the Nano. Work from the top: power first, then each part, then the code.
0 of 5 checked
Power🔧 DC volts, 20 V rangeCheck 1 of 5
Nano supply pin
Plug the Nano into USB. Black probe on a GND pin, red probe on the 5V pin of the board.
You should see: 4.6 to 5.3 V
Readings are compared with the ranges for this build's parts. A meter on the wrong range or a loose probe gives odd numbers: check those first.
Common faults in this build
Noisy, wandering trace: what should I check?
Dry the skin, press the pads, sit still, keep cables from swinging.
No R peaks: what should I check?
Check pad positions and the RL pad.
Bpm jumps: what should I check?
Threshold too low; sit still for a few seconds while it adapts.
Plot flat at 0: what should I check?
A lead is off or a pad is dry.
Heavy hum: what should I check?
Keep away from mains cables and chargers.