Fault finder: Door left-ajar chime
6 checks for this build on the Nano. Work from the top: power first, then each part, then the code.
0 of 6 checked
Power🔧 DC volts, 20 V rangeCheck 1 of 6
Nano supply pin
Plug the Nano into USB. Black probe on a GND pin, red probe on the 5V pin of the board.
You should see: 4.6 to 5.3 V
Readings are compared with the ranges for this build's parts. A meter on the wrong range or a loose probe gives odd numbers: check those first.
Common faults in this build
No reaction: what should I check?
Flip the magnet, only one pole works, and check the pin order.
Always reads closed: what should I check?
Check the 10 kilohm pull-up and pin 3 wire.
Chimes too early: what should I check?
Raise OPEN_LIMIT_MS.
False openings: what should I check?
The magnet is too far, move it closer.
Buzzer silent: what should I check?
Check it is an active buzzer and the polarity.