Fault finder: Digital weighing scale
7 checks for this build on the Uno. Work from the top: power first, then each part, then the code.
0 of 7 checked
Power🔧 DC volts, 20 V rangeCheck 1 of 7
Uno supply pin
Plug the Uno into USB. Black probe on a GND pin, red probe on the 5V pin of the board.
You should see: 4.6 to 5.3 V
Readings are compared with the ranges for this build's parts. A meter on the wrong range or a loose probe gives odd numbers: check those first.
Common faults in this build
Weights read negative: what should I check?
Swap the white and green wires (A+ and A−).
Wild jumps: what should I check?
The cell is touching the base. Only the screwed ends should touch the plates.
Always 0 or no change: what should I check?
Check DT and SCK are not swapped, and the cell's wire colours on your module's sheet.
Slow creep: what should I check?
Normal for cheap cells. Tare just before weighing.