Fault finder: Digital weighing scale

7 checks for this build on the Uno. Work from the top: power first, then each part, then the code.

0 of 7 checked
Power🔧 DC volts, 20 V rangeCheck 1 of 7

Uno supply pin

Plug the Uno into USB. Black probe on a GND pin, red probe on the 5V pin of the board.

You should see: 4.6 to 5.3 V

V

Readings are compared with the ranges for this build's parts. A meter on the wrong range or a loose probe gives odd numbers: check those first.

Common faults in this build

Weights read negative: what should I check?

Swap the white and green wires (A+ and A−).

Wild jumps: what should I check?

The cell is touching the base. Only the screwed ends should touch the plates.

Always 0 or no change: what should I check?

Check DT and SCK are not swapped, and the cell's wire colours on your module's sheet.

Slow creep: what should I check?

Normal for cheap cells. Tare just before weighing.