Fault finder: Dew point and mould risk alarm
10 checks for this build on the Nano. Work from the top: power first, then each part, then the code.
0 of 10 checked
Power🔧 DC volts, 20 V rangeCheck 1 of 10
Nano supply pin
Plug the Nano into USB. Black probe on a GND pin, red probe on the 5V pin of the board.
You should see: 4.6 to 5.3 V
Readings are compared with the ranges for this build's parts. A meter on the wrong range or a loose probe gives odd numbers: check those first.
Common faults in this build
Display and sensor do not both work: what should I check?
Two devices cannot share an address. Run an I2C scanner and fix the address in the code.
Readings are NaN: what should I check?
Check SDA and SCL are not swapped and the sensor has power.
Humidity seems too high near a heater: what should I check?
The sensor is warmed by something nearby. Move it away from the board and regulator.
Alarm never stops in a bathroom: what should I check?
That may be correct after showers. Raise RH_LIMIT or add a fan.