Projects / Desk motion counter / Fault finder

Fault finder: Desk motion counter

12 checks for this build on the Uno. Work from the top: power first, then each part, then the code.

0 of 12 checked
Power🔧 DC volts, 20 V rangeCheck 1 of 12

Uno supply pin

Plug the Uno into USB. Black probe on a GND pin, red probe on the 5V pin of the board.

You should see: 4.6 to 5.3 V

V

Readings are compared with the ranges for this build's parts. A meter on the wrong range or a loose probe gives odd numbers: check those first.

Common faults in this build

Counts several times per visit: what should I check?

Jumper on H, or hold time too short: use L and add a 5 s lock-out in code.

Never triggers: what should I check?

Wait the 30 s warm-up, and point the dome at where people move.

Display blank: what should I check?

CLK and DIO swapped.