Fault finder: Cricket thermometer
13 checks for this build on the Nano. Work from the top: power first, then each part, then the code.
0 of 13 checked
Power🔧 DC volts, 20 V rangeCheck 1 of 13
Nano supply pin
Plug the Nano into USB. Black probe on a GND pin, red probe on the 5V pin of the board.
You should see: 4.6 to 5.3 V
Readings are compared with the ranges for this build's parts. A meter on the wrong range or a loose probe gives odd numbers: check those first.
Common faults in this build
Sensor reads minus 127: what should I check?
Check the wiring and the 4.7 kilohm pull-up on D4.
Blank screen: what should I check?
Check A4 and A5 and the OLED address.
Result is far off: what should I check?
The rule works best for snowy tree crickets in warm weather.
Chirps counted twice: what should I check?
Increase the 40 millisecond lockout.
Display text cut off: what should I check?
Shorten the lines or use a smaller text size.