Fault finder: Control surface angle gauge
12 checks for this build on the Nano. Work from the top: power first, then each part, then the code.
0 of 12 checked
Power🔧 DC volts, 20 V rangeCheck 1 of 12
Nano supply pin
Plug the Nano into USB. Black probe on a GND pin, red probe on the 5V pin of the board.
You should see: 4.6 to 5.3 V
Readings are compared with the ranges for this build's parts. A meter on the wrong range or a loose probe gives odd numbers: check those first.
Common faults in this build
Angle jumps around: what should I check?
Hold the model still, the sensor reads motion as well as gravity.
Reads zero or nonsense: what should I check?
Check A4 and A5 and the MPU6050 address at 0x68.
Angle is wrong by a large amount: what should I check?
Mount the sensor with its X axis along the hinge.
Blank screen: what should I check?
Check the OLED address.
Max values never clear: what should I check?
Hold the button for a full second.