Fault finder: Control surface angle gauge

12 checks for this build on the Nano. Work from the top: power first, then each part, then the code.

0 of 12 checked
Power🔧 DC volts, 20 V rangeCheck 1 of 12

Nano supply pin

Plug the Nano into USB. Black probe on a GND pin, red probe on the 5V pin of the board.

You should see: 4.6 to 5.3 V

V

Readings are compared with the ranges for this build's parts. A meter on the wrong range or a loose probe gives odd numbers: check those first.

Common faults in this build

Angle jumps around: what should I check?

Hold the model still, the sensor reads motion as well as gravity.

Reads zero or nonsense: what should I check?

Check A4 and A5 and the MPU6050 address at 0x68.

Angle is wrong by a large amount: what should I check?

Mount the sensor with its X axis along the hinge.

Blank screen: what should I check?

Check the OLED address.

Max values never clear: what should I check?

Hold the button for a full second.