Fault finder: Cold storage door and temperature alarm

12 checks for this build on the Nano. Work from the top: power first, then each part, then the code.

0 of 12 checked
Power🔧 DC volts, 20 V rangeCheck 1 of 12

Nano supply pin

Plug the Nano into USB. Black probe on a GND pin, red probe on the 5V pin of the board.

You should see: 4.6 to 5.3 V

V

Readings are compared with the ranges for this build's parts. A meter on the wrong range or a loose probe gives odd numbers: check those first.

Common faults in this build

Probe reads -127: what should I check?

Not found. Check the 4.7 kΩ pull-up and wires.

Buzzer on all the time: what should I check?

The relay is active low or high the other way. Swap the HIGH and LOW writes.

Relay clicks but buzzer silent: what should I check?

Check COM and NO wiring and the 12 V supply.

Nano resets when the relay clicks: what should I check?

Add a 470 µF capacitor on the 5 V rail.