Fault finder: Cold storage door and temperature alarm
12 checks for this build on the Nano. Work from the top: power first, then each part, then the code.
0 of 12 checked
Power🔧 DC volts, 20 V rangeCheck 1 of 12
Nano supply pin
Plug the Nano into USB. Black probe on a GND pin, red probe on the 5V pin of the board.
You should see: 4.6 to 5.3 V
Readings are compared with the ranges for this build's parts. A meter on the wrong range or a loose probe gives odd numbers: check those first.
Common faults in this build
Probe reads -127: what should I check?
Not found. Check the 4.7 kΩ pull-up and wires.
Buzzer on all the time: what should I check?
The relay is active low or high the other way. Swap the HIGH and LOW writes.
Relay clicks but buzzer silent: what should I check?
Check COM and NO wiring and the 12 V supply.
Nano resets when the relay clicks: what should I check?
Add a 470 µF capacitor on the 5 V rail.