Fault finder: Cattle water trough refill controller

9 checks for this build on the Nano. Work from the top: power first, then each part, then the code.

0 of 9 checked
Power🔧 DC volts, 20 V rangeCheck 1 of 9

Nano supply pin

Plug the Nano into USB. Black probe on a GND pin, red probe on the 5V pin of the board.

You should see: 4.6 to 5.3 V

V

Readings are compared with the ranges for this build's parts. A meter on the wrong range or a loose probe gives odd numbers: check those first.

Common faults in this build

Pump runs backwards in logic: what should I check?

The floats close the other way. Flip the logic constants.

Pump chatters: what should I check?

Water sloshes around the floats. Use a stilling tube or add a short delay.

Relay does not click: what should I check?

Check the 5 V supply and the relay IN wiring.

Buzzer sounds with water present: what should I check?

A float is stuck. Check it moves freely.