Fault finder: Cattle water trough refill controller
9 checks for this build on the Nano. Work from the top: power first, then each part, then the code.
0 of 9 checked
Power🔧 DC volts, 20 V rangeCheck 1 of 9
Nano supply pin
Plug the Nano into USB. Black probe on a GND pin, red probe on the 5V pin of the board.
You should see: 4.6 to 5.3 V
Readings are compared with the ranges for this build's parts. A meter on the wrong range or a loose probe gives odd numbers: check those first.
Common faults in this build
Pump runs backwards in logic: what should I check?
The floats close the other way. Flip the logic constants.
Pump chatters: what should I check?
Water sloshes around the floats. Use a stilling tube or add a short delay.
Relay does not click: what should I check?
Check the 5 V supply and the relay IN wiring.
Buzzer sounds with water present: what should I check?
A float is stuck. Check it moves freely.