Fault finder: CAN bus between two Arduinos
9 checks for this build on the Nano. Work from the top: power first, then each part, then the code.
0 of 9 checked
Power🔧 DC volts, 20 V rangeCheck 1 of 9
Nano supply pin
Plug the Nano into USB. Black probe on a GND pin, red probe on the 5V pin of the board.
You should see: 4.6 to 5.3 V
Readings are compared with the ranges for this build's parts. A meter on the wrong range or a loose probe gives odd numbers: check those first.
Common faults in this build
CAN init failed: what should I check?
Check the SPI wiring, CS pin and the crystal setting (MCP_8MHZ or MCP_16MHZ).
No messages received: what should I check?
Check CANH and CANL are not swapped and the grounds are joined.
Garbage at the receiver: what should I check?
Both nodes must use the same speed and the same crystal setting.
Intermittent errors: what should I check?
Check termination at both ends and keep wires short and twisted.