Fault finder: Blue Pill comfort index meter

9 checks for this build on the board. Work from the top: power first, then each part, then the code.

0 of 9 checked
Power🔧 DC volts, 20 V rangeCheck 1 of 9

board supply pin

Plug the board into USB. Black probe on a GND pin, red probe on the 5V pin of the board.

You should see: 4.6 to 5.3 V

V

Readings are compared with the ranges for this build's parts. A meter on the wrong range or a loose probe gives odd numbers: check those first.

Common faults in this build

Sensor read failed: what should I check?

Check the address 0x44 or 0x45 and the I2C wires.

Temperature reads high: what should I check?

Move the sensor away from the board and display.

Humidity looks wrong: what should I check?

Let the sensor settle after a change, and keep it dry and away from steam jets.

Display blank: what should I check?

Check the I2C address 0x3C.

Upload problems: what should I check?

Check the ST-Link wires and the board settings.