Fault finder: Blue Pill comfort index meter
9 checks for this build on the board. Work from the top: power first, then each part, then the code.
0 of 9 checked
Power🔧 DC volts, 20 V rangeCheck 1 of 9
board supply pin
Plug the board into USB. Black probe on a GND pin, red probe on the 5V pin of the board.
You should see: 4.6 to 5.3 V
Readings are compared with the ranges for this build's parts. A meter on the wrong range or a loose probe gives odd numbers: check those first.
Common faults in this build
Sensor read failed: what should I check?
Check the address 0x44 or 0x45 and the I2C wires.
Temperature reads high: what should I check?
Move the sensor away from the board and display.
Humidity looks wrong: what should I check?
Let the sensor settle after a change, and keep it dry and away from steam jets.
Display blank: what should I check?
Check the I2C address 0x3C.
Upload problems: what should I check?
Check the ST-Link wires and the board settings.