Fault finder: Blue Pill humidity gauge

11 checks for this build on the board. Work from the top: power first, then each part, then the code.

0 of 11 checked
Power🔧 DC volts, 20 V rangeCheck 1 of 11

board supply pin

Plug the board into USB. Black probe on a GND pin, red probe on the 5V pin of the board.

You should see: 4.6 to 5.3 V

V

Readings are compared with the ranges for this build's parts. A meter on the wrong range or a loose probe gives odd numbers: check those first.

Common faults in this build

Sensor read failed: what should I check?

Check the data pin, the pull-up and 3.3 V power.

No display: what should I check?

Check the OLED address and I2C wires.

Values jump: what should I check?

Keep the sensor away from heat and air flow.

Compile error on DHT: what should I check?

Install the Adafruit Unified Sensor library as well.

Upload fails: what should I check?

Check the ST-Link wires and boot jumpers.