9 checks for this build on the board. Work from the top: power first, then each part, then the code.
0 of 9 checked
Power🔧 DC volts, 20 V rangeCheck 1 of 9
board supply pin
Plug the board into USB. Black probe on a GND pin, red probe on the 5V pin of the board.
You should see: 4.6 to 5.3 V
Readings are compared with the ranges for this build's parts. A meter on the wrong range or a loose probe gives odd numbers: check those first.
Common faults in this build
Display stays blank: what should I check?
Check CLK, DIO and power, and the pin names.
Time runs fast or slow: what should I check?
Check the board crystal and the timer frequency setting.
Buttons act twice: what should I check?
Check wiring to GND and the debounce.
Digits look odd: what should I check?
Check the display is a 4-digit TM1637 with a colon.
Upload fails: what should I check?
Check the ST-Link wires and the board settings.