Fault finder: Bidirectional visitor counter with room light
7 checks for this build on the Uno. Work from the top: power first, then each part, then the code.
0 of 7 checked
Power🔧 DC volts, 20 V rangeCheck 1 of 7
Uno supply pin
Plug the Uno into USB. Black probe on a GND pin, red probe on the 5V pin of the board.
You should see: 4.6 to 5.3 V
Readings are compared with the ranges for this build's parts. A meter on the wrong range or a loose probe gives odd numbers: check those first.
Common faults in this build
Counts the wrong way: what should I check?
Swap the D2 and D3 wires.
Counts twice: what should I check?
Sensors too far apart or set too far. Move them closer and shorten their range.
Misses people: what should I check?
IR modules struggle with black clothes and sunlight. Use them indoors, or use two VL53L0X sensors for longer range.