Fault finder: Battery discharge curve analyser
10 checks for this build on the Nano. Work from the top: power first, then each part, then the code.
0 of 10 checked
Power🔧 DC volts, 20 V rangeCheck 1 of 10
Nano supply pin
Plug the Nano into USB. Black probe on a GND pin, red probe on the 5V pin of the board.
You should see: 4.6 to 5.3 V
Readings are compared with the ranges for this build's parts. A meter on the wrong range or a loose probe gives odd numbers: check those first.
Common faults in this build
Current is wrong: what should I check?
Check the sense resistor value and the op-amp wiring.
MOSFET very hot: what should I check?
Lower the current or enlarge the heatsink.
Stops too early: what should I check?
The cell's own protection may have acted.