Fault finder: Automatic sliding door model

8 checks for this build on the Uno. Work from the top: power first, then each part, then the code.

0 of 8 checked
Power🔧 DC volts, 20 V rangeCheck 1 of 8

Uno supply pin

Plug the Uno into USB. Black probe on a GND pin, red probe on the 5V pin of the board.

You should see: 4.6 to 5.3 V

V

Readings are compared with the ranges for this build's parts. A meter on the wrong range or a loose probe gives odd numbers: check those first.

Common faults in this build

Motor runs the wrong way: what should I check?

Swap the two motor wires.

Door never stops: what should I check?

Check the limit switch wiring to GND.

Motor stutters: what should I check?

Weak batteries; use fresh cells.