Projects / Talking thermometer / Fault finder

Fault finder: Talking thermometer

11 checks for this build on the Nano. Work from the top: power first, then each part, then the code.

0 of 11 checked
Power🔧 DC volts, 20 V rangeCheck 1 of 11

Nano supply pin

Plug the Nano into USB. Black probe on a GND pin, red probe on the 5V pin of the board.

You should see: 4.6 to 5.3 V

V

Readings are compared with the ranges for this build's parts. A meter on the wrong range or a loose probe gives odd numbers: check those first.

Common faults in this build

Silent: what should I check?

Check file names and the MP3 folder.

Words overlap: what should I check?

Raise WORD_MS to your longest clip.

Reads minus 127: what should I check?

Check the probe wiring and pull-up.

Wrong number: what should I check?

Check the digit clip numbering.