Fault finder: Applause meter
9 checks for this build on the Nano. Work from the top: power first, then each part, then the code.
0 of 9 checked
Power🔧 DC volts, 20 V rangeCheck 1 of 9
Nano supply pin
Plug the Nano into USB. Black probe on a GND pin, red probe on the 5V pin of the board.
You should see: 4.6 to 5.3 V
Readings are compared with the ranges for this build's parts. A meter on the wrong range or a loose probe gives odd numbers: check those first.
Common faults in this build
Top lights always on: what should I check?
Turn the module's knob to lower the sensitivity.
Nothing lights: what should I check?
Turn the knob up and check AO goes to A0.
A light never lights: what should I check?
Check its resistor and the direction of the LED.
Round never starts: what should I check?
Check the button goes to D10 and GND.
Bar flickers: what should I check?
Normal for speech, the peak light shows the top.