Fault finder: Breath alcohol tester

11 checks for this build on the Nano. Work from the top: power first, then each part, then the code.

0 of 11 checked
Power🔧 DC volts, 20 V rangeCheck 1 of 11

Nano supply pin

Plug the Nano into USB. Black probe on a GND pin, red probe on the 5V pin of the board.

You should see: 4.6 to 5.3 V

V

Readings are compared with the ranges for this build's parts. A meter on the wrong range or a loose probe gives odd numbers: check those first.

Common faults in this build

Always High: what should I check?

The sensor has not warmed up, or the baseline was taken near a vapour.

Never rises: what should I check?

Check AO to A0 and the 5 V supply.

Readings drift: what should I check?

Humidity and temperature change MQ-3 values. Re-take the baseline.

Screen blank: what should I check?

Check the I2C connection.