Fault finder: Barometric storm warning
11 checks for this build on the Nano. Work from the top: power first, then each part, then the code.
0 of 11 checked
Power🔧 DC volts, 20 V rangeCheck 1 of 11
Nano supply pin
Plug the Nano into USB. Black probe on a GND pin, red probe on the 5V pin of the board.
You should see: 4.6 to 5.3 V
Readings are compared with the ranges for this build's parts. A meter on the wrong range or a loose probe gives odd numbers: check those first.
Common faults in this build
Sensor not found: what should I check?
Check I2C address 0x76 or 0x77.
Readings jump: what should I check?
Keep the sensor away from air currents.
Never warns: what should I check?
Check the 3 hPa rule and the interval.
Display blank: what should I check?
Check the OLED address 0x3C.