Fault finder: Digital protractor
11 checks for this build on the Nano. Work from the top: power first, then each part, then the code.
0 of 11 checked
Power🔧 DC volts, 20 V rangeCheck 1 of 11
Nano supply pin
Plug the Nano into USB. Black probe on a GND pin, red probe on the 5V pin of the board.
You should see: 4.6 to 5.3 V
Readings are compared with the ranges for this build's parts. A meter on the wrong range or a loose probe gives odd numbers: check those first.
Common faults in this build
Does not start: what should I check?
Check the sensor wires and the address 0x53.
Angle is always 0: what should I check?
Check SDA and SCL are not swapped and the library is installed.
Number jumps: what should I check?
Hold the board still, and keep wires from pulling on it.
Wrong by a few degrees: what should I check?
Use the zero button on a surface you trust.
Reads 90 flat: what should I check?
Mount the board so the X to Z plane is the one you want to measure.