Fault finder: Three-axis g meter
11 checks for this build on the Nano. Work from the top: power first, then each part, then the code.
0 of 11 checked
Power🔧 DC volts, 20 V rangeCheck 1 of 11
Nano supply pin
Plug the Nano into USB. Black probe on a GND pin, red probe on the 5V pin of the board.
You should see: 4.6 to 5.3 V
Readings are compared with the ranges for this build's parts. A meter on the wrong range or a loose probe gives odd numbers: check those first.
Common faults in this build
Readings off by a lot: what should I check?
Check that 3V3 is wired to AREF.
Always zero: what should I check?
Check the supply and the axis wires.
Z not 1 g: what should I check?
Fix COUNTS_PER_G with the flip test.
Noisy numbers: what should I check?
Keep the sensor wires short and away from the display.
Chip very hot: what should I check?
5 V on a bare chip, disconnect it at once.