Fault finder: AAA battery life gauge
9 checks for this build on the Nano. Work from the top: power first, then each part, then the code.
0 of 9 checked
Power🔧 DC volts, 20 V rangeCheck 1 of 9
Nano supply pin
Plug the Nano into USB. Black probe on a GND pin, red probe on the 5V pin of the board.
You should see: 4.6 to 5.3 V
Readings are compared with the ranges for this build's parts. A meter on the wrong range or a loose probe gives odd numbers: check those first.
Common faults in this build
Reads zero: what should I check?
Check the divider middle point and the A0 wire.
Reads half the real voltage: what should I check?
The divider factor is wrong, check both resistors are 10 kohm.
Reading jumps: what should I check?
Poor contact at the battery clips.
Bar always full: what should I check?
Raise FULL_V and EMPTY_V to match your cells.
Nano resets: what should I check?
The cells are connected to the 5V pin by mistake, remove them at once.