Fault finder: 4–20 mA sensor reader
7 checks for this build on the Nano. Work from the top: power first, then each part, then the code.
0 of 7 checked
Power🔧 DC volts, 20 V rangeCheck 1 of 7
Nano supply pin
Plug the Nano into USB. Black probe on a GND pin, red probe on the 5V pin of the board.
You should see: 4.6 to 5.3 V
Readings are compared with the ranges for this build's parts. A meter on the wrong range or a loose probe gives odd numbers: check those first.
Common faults in this build
Always 0 mA: what should I check?
Check the shunt is in the current path and A0 is on its top side.
Reading too high or low: what should I check?
Measure the shunt's actual resistance and put it in the code.
LCD blank: what should I check?
Check I2C address 0x27 or 0x3F and the contrast screw.
ADS1115 not found: what should I check?
Check the I2C wires and VDD.